Calman 3D LUT校准方案- Monitor
SmallHD Monitor Calibration Guide
Use this step-by-step guide to create a corrective 3D LUT for your SmallHD monitor with CalMAN. After creating the 3D LUT, upload the file into the display using a USB drive or SD Card.
CalMAN Required Version
- CalMAN 2019 5.9.0 or higher
SmallHD Required Firmware
- Version 3.0 or higher
Step 1
- From the CalMAN Menu in the top-left, choose Open Workflow Template and then ColorCube (3D LUT) Workflow
- Click Next on the first page to proceed to hardware connection
Connect your Colorimeter and Pattern Generator to CalMAN.
- Plug your meter into a USB port on the computer and press the Find Meter button on the left
- When your meter is connected, select your display type from the dropdown (this will vary by meter)
- C6 Meters - LCD (LED White)
- When your meter is connected, select your display type from the dropdown (this will vary by meter)
- Connect Pattern Source to your computer.
- Click the Find Source button then select your source
- Select the pattern window size
- Window 10%
Connect to the CalMAN Cube Generator
- Click Find 3D LUT Device Button
- Choose Make: SpectraCal and Model: Cube Generator (3D LUT)
- Click Connect
Prepare your SmallHD Monitor for calibration
- Press the Settings button on the front of the monitor to open the SmallHD Menu
- Navigate to the Display section and choose Calibration
- Uncheck the Enable Calibration LUT box.
- This sets the display into its native color space, which is necessary for calibration.
- Navigate to the Backlight settings, check Studio Brightness to set luminance
- You can also use the Luminance Target page (in the "optimize display" section) to set a custom luminance
- Close the SmallHD Menu
Step 2
Select your calibration targets
-
Select:
- Input Signal Levels: Video (16-235)
- Lum. Response Target: Choose Power and enter 2.4
- Color Gamut Target: Rec.709/sRGB or desired target
- White Point Target: D65 or desired target
Step 3
In this step, you'll take readings of your display before the calibration. These will be used to compare your calibration results
- To take Pre-Calibration Measurements click the Read Series [...] button to measure the display's grayscale and ColorChecker response
- This will provide a point of reference to compare your calibration results
Step 4
This page gives an estimate on the ability of the displays current state to be calibrated by a 3D LUT
- This step will usually show multiple red indicators, as the pre-calibration readings are taken in panel native mode. Skip this page regardless of readings
- This page is designed more for using an external 3D LUT device.
Step 5
NOTE: Skip 1D Ramp LUT page, SmallHD monitors do not require 1D LUTs.
Here we will create the 3D Calibration LUT
- Click the AutoCal button in the bottom right-hand corner of the Create 3D Cube LUT page
- On the AutoCal Setup dialog choose:
- Calibration Type: IR Profile (Point Based) Points: 3000
- This configuration proved best during in-house testing, others may be used but your results may vary. For an explanation of the different types of 3D LUTs CalMAN can create see THIS ARTICLE
- Video Range: SMPTE (16-235)
- Calibration Type: IR Profile (Point Based) Points: 3000
- Note 3D LUT File Path
- Default: /Documents/SpectraCal/CalMAN/LUTs
- You may write directly to the USB drive or SD Card you will use to move the LUT to the monitor
- Click OK to begin AutoCal process
Step 6
Transfer CalMAN Generated 3D LUT from your computer to the SmallHD Monitor
- Copy the 3D LUT Generated in Step 5 from your the documents folder, or location where it was saved, to a USB Drive or SD Card
- Plug the USB Drive or SD Card into the display, on most models these ports are behind a rubber door on the lower front of the monitor.
- Press the Settings button on the front of the monitor to open the SmallHD Menu
- Navigate to the Display section and choose Calibration
- CHECK the Enable Calibration LUT box.
- Press down on the navigation joystick to the Calibration LUT selection
- Choose the 3D LUT that was saved to your storage device
- The monitor will confirm the calibration targets, choose your targets and confirm.
- Close the SmallHD Menu
Step 7
Post-calibration readings to document the post-calibration condition of the display.
- Click the Read Series [...] button
If you have any question ,pls let me know ,my email is jenk@starcctv.cn ,thanks for you watch !